Home AC/AC LVDT works under pressure and temperature extremes.
 

Keywords :   


AC/AC LVDT works under pressure and temperature extremes.

2014-08-04 14:31:27| Industrial Newsroom - All News for Today

Rated for pressures to 35,000 psi at continuous temperatures to 450°F, High-Temperature High-Pressure Linear Displacement Transducers (LVDTs) have .30 in. OD body with perforated housing that equalizes internal and external pressure. Fluids must be electrically non-conductive and chemically benign, since holes in housing expose internal coils. Non-linearity is ±0.25%, and temperature coefficient of sensitivity is ±0.01%/°F. Signal conditioners for DC/DC or 4–20 mA operation are available. This story is related to the following:LVDT Transducers

Tags: works pressure temperature extremes

Category:Industrial Goods and Services