Moving Violations Video No. 177: Conduit Catastrophe

2018-10-18 17:28:31| Electrical Construction & Maintenance

Russ runs across an interesting wiring connection for a roadside sign.

Tags: video moving violations conduit

 

Moving Violations Video No. 176: Dangerously Close to Porch Area

2018-10-04 00:26:52| Electrical Construction & Maintenance

In this episode, Russ shows us some overhead service conductors that are run way too close to an outdoor porch/deck area of a dwelling unit. As per Sec. 230.9(A) of the 2017 NEC, these conductors must be located at least 3 ft away from the edge of th

Tags: video area close moving

 
 

Moving Violations Video No. 175: Improper Support and Lack of Protection

2018-09-20 17:27:35| Electrical Construction & Maintenance

In this episode, Russ points out two violations at this switch location. The first problem is this box is improperly supported by electrical metallic tubing (EMT). As per Sec. 358.12(2), EMT is not allowed to support a box. The second problem is the

Tags: of video support protection

 

Moving Violations Video No. 174: Took the Easy Way Out

2018-09-06 16:26:33| Electrical Construction & Maintenance

In this episode, Russ shows us a violation of Sec. 300.11(C) of the 2017 NEC. This electrician took the easy way out when they installed this liquidtight flexible metal conduit (LFMC). Instead of installing the LFMC on its own supports, they simply a

Tags: out video way easy

 

Moving Violations Video No. 173: Hung Out to Dry

2018-08-23 17:27:40| Electrical Construction & Maintenance

In this episode, Russ shows us a violation of Sec. 314.23 of the 2017 NEC. Someone decided to stick a metal box on the end of this piece of metal conduit and secure it with a locknut. This serves as the only means of support for this box.

Tags: to video moving dry

 